AL4RPV-50A Plenum Rated 1/2" Heliax Aluminum Coaxial Cable, White Jacket, Andrew

$3.35
In stock
SKU
AL4RPV-50
  • Buy 50 for $2.95 each and save 12%
  • Buy 100 for $2.75 each and save 18%
  • Buy 500 for $2.55 each and save 24%

AL4RPV-50A Plenum Rated 1/2" Heliax Corrugated Aluminum Coaxial Cable, 1/2 in, off white PVC jacket, MFR: Andrew / Commscope

 

 

AL4RPV-50A Plenum Rated 1/2" Heliax Corrugated Aluminum Coaxial Cable, 1/2 in, off white PVC jacket

MFR: Andrew / Commscope

 *Special Order. Please Call To Order.  Normal delivery is 2-3 days ARO.

 

Product Specifications

 

Product Classification  
Brand   HELIAX®
Product Type   Air coaxial cable
   
Construction Materials  
Jacket Material   PVC
Dielectric Material   PE spline
Flexibility   Standard
Inner Conductor Material   Copper-clad aluminum wire
Jacket Color   Off-white
Outer Conductor Material   Corrugated aluminum
   
Dimensions  
Nominal Size   1/2 in
Cable Weight   0.21 kg/m   |   0.14 lb/ft
Diameter Over Jacket   15.748 mm   |   0.620 in
Inner Conductor OD   4.5720 mm   |   0.1800 in
Outer Conductor OD   14.046 mm   |   0.553 in
   
Electrical Specifications  
Cable Impedance   50 ohm ±2 ohm
Capacitance   76.0 pF/m   |   23.0 pF/ft
dc Resistance, Inner Conductor   1.570 ohms/km   |   0.480 ohms/kft
dc Resistance, Outer Conductor   1.570 ohms/km   |   0.480 ohms/kft
dc Test Voltage   4000 V
Inductance   0.190 µH/m   |   0.058 µH/ft
Insulation Resistance   100000 Mohms•km
Jacket Spark Test Voltage (rms)   5000 V
Operating Frequency Band   1 – 6000 MHz
Peak Power   40.0 kW
Power Attenuation   2.325
Pulse Reflection   0.5%
Velocity   88%
   
Environmental Specifications  
Installation Temperature   -5 °C to +60 °C (+23 °F to +140 °F)
Operating Temperature   -20 °C to +85 °C (-4 °F to +185 °F)
Storage Temperature   -20 °C to +85 °C (-4 °F to +185 °F)
   
General Specifications  
Brand   HELIAX®
Ordering Note   CommScope® standard product (Global)
   
Mechanical Specifications  
Bending Moment   6.8 N-m   |   5.0 ft lb
Fire Retardancy Test Method   NFPA 262/CATVP/CMP
Flat Plate Crush Strength   1.4 kg/mm   |   80.0 lb/in
Minimum Bend Radius, Multiple Bends   127.00 mm   |   5.00 in
Minimum Bend Radius, Single Bend   64.00 mm   |   2.50 in
Number of Bends, minimum   15
Tensile Strength   79 kg   |   175 lb
   
Note  
Performance Note   Values typical, unless otherwise stated
   
Standard Conditions  
Attenuation, Ambient Temperature   20 °C   |   68 °F
Average Power, Ambient Temperature   40 °C   |   104 °F
Average Power, Inner Conductor Temperature   100 °C   |   212 °F
Return Loss/VSWR
Frequency Band VSWR Return Loss (dB)
700–894 MHz 1.13 24.30
806–960 MHz 1.13 24.30
1700–2200 MHz 1.13 24.30
Attenuation

Enter a specific frequency to view its attenuation:  
 
Attenuation
Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW)
0.5 0.152 0.046 40.00
1 0.216 0.066 35.37
1.5 0.264 0.081 28.84
2 0.306 0.093 24.95
10 0.691 0.211 11.04
20 0.985 0.3 7.75
30 1.213 0.37 6.29
50 1.581 0.482 4.83
85 2.087 0.636 3.66
88 2.126 0.648 3.59
100 2.274 0.693 3.35
108 2.368 0.722 3.22
150 2.821 0.86 2.70
174 3.054 0.931 2.50
200 3.292 1.003 2.32
204 3.327 1.014 2.29
300 4.104 1.251 1.86
400 4.808 1.466 1.59
450 5.134 1.565 1.49
500 5.445 1.659 1.40
512 5.517 1.682 1.38
600 6.032 1.839 1.26
700 6.583 2.007 1.16
800 7.105 2.166 1.07
824 7.227 2.203 1.06
894 7.574 2.308 1.01
960 7.892 2.405 0.97
1000 8.081 2.463 0.94
1218 9.068 2.764 0.84
1250 9.207 2.806 0.83
1500 10.256 3.126 0.74
1700 11.053 3.369 0.69
1794 11.416 3.48 0.67
1800 11.439 3.487 0.67
2000 12.192 3.716 0.63
2100 12.559 3.828 0.61
2200 12.92 3.938 0.59
2300 13.276 4.046 0.57
2500 13.975 4.259 0.55
2700 14.656 4.467 0.52
3000 15.649 4.77 0.49
3400 16.928 5.159 0.45
3700 17.859 5.443 0.43
4000 18.768 5.72 0.41
5000 21.671 6.605 0.35
6000 24.42 7.443 0.31

 

More Information
Call For Price No
Featured Product No
Made in the USA No
NOS No
Manufacturer Name ANDREW / COMMSCOPE
We found other products you might like!