AVA5RK-50, HELIAX® Andrew Virtual Air™ Coaxial Cable, corrugated copper, 7/8 in, black non-halogenated, fire retardant polyolefin jacket B2ca- s1a, d1,a1
NOTE: THIS CABLE IS SPECIAL ORDER FROM FACTORY. NORMAL LEAD TIME IS 2-3 WEEKS ARO.
AVA5RK-50, HELIAX® Andrew Virtual Air™ Coaxial Cable, corrugated copper, 7/8 in, black non-halogenated, fire retardant polyolefin jacket B2ca- s1a, d1,a1
NOTE: THIS CABLE IS SPECIAL ORDER FROM FACTORY. NORMAL LEAD TIME IS 2-3 WEEKS.
Product Classification
Brand
HELIAX®
Product Series
AVA5-50
Product Type
Coaxial wireless cable
Standards And Qualifications
EN50575 CPR Cable EuroClass
B2ca | s1a | d1 | a1
Construction Materials
Jacket Material
Non-halogenated, fire retardant polyolefin
Outer Conductor Material
Corrugated copper
Dielectric Material
Foam PE
Flexibility
Standard
Inner Conductor Material
Copper tube
Jacket Color
Black
Dimensions
Nominal Size
7/8 in
Cable Weight
0.35 lb/ft | 0.53 kg/m
Diameter Over Dielectric
24.130 mm | 0.950 in
Diameter Over Jacket
27.940 mm | 1.100 in
Inner Conductor OD
9.4488 mm | 0.3720 in
Outer Conductor OD
25.400 mm | 1.000 in
Electrical Specifications
Cable Impedance
50 ohm ±1 ohm
Capacitance
22.3 pF/ft | 73.2 pF/m
dc Resistance, Inner Conductor
0.410 ohms/kft | 1.435 ohms/km
dc Resistance, Outer Conductor
0.340 ohms/kft | 1.116 ohms/km
dc Test Voltage
6000 V
Inductance
0.184 µH/m | 0.056 µH/ft
Insulation Resistance
100000 Mohms•km
Jacket Spark Test Voltage (rms)
8000 V
Operating Frequency Band
1 – 5000 MHz
Peak Power
91.0 kW
Velocity
91%
Environmental Specifications
Installation Temperature
-40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature
-40 °C to +60 °C (-40 °F to +140 °F)
Storage Temperature
-40 °C to +60 °C (-40 °F to +140 °F)
General Specifications
Specification Sheet Revision Level
B
Mechanical Specifications
Bending Moment
19.0 N-m | 14.0 ft lb
Fire Retardancy Test Method
NFPA 130-2010 | UL 1666/CATVR/CMR
Flat Plate Crush Strength
75.0 lb/in
Minimum Bend Radius, Multiple Bends
254.00 mm | 10.00 in
Minimum Bend Radius, Single Bend
127.00 mm | 5.00 in
Number of Bends, minimum
15
Number of Bends, typical
30
Smoke Index Test Method
IEC 61034
Tensile Strength
159 kg | 350 lb
Toxicity Index Test Method
IEC 60754-1 | IEC 60754-2
Note
Performance Note
Values typical, unless otherwise stated
Standard Conditions
Attenuation, Ambient Temperature
20 °C | 68 °F
Average Power, Ambient Temperature
40 °C | 104 °F
Average Power, Inner Conductor Temperature
100 °C | 212 °F
Return Loss/VSWR
Frequency Band
VSWR
Return Loss (dB)
680–800 MHz
1.13
24.30
800–960 MHz
1.13
24.30
1700–2200 MHz
1.13
24.30
Attenuation Enter a specific frequency to view its attenuation: