F1TNR-HC Type-N Male Connector, Right Angle, FSJ1-50A

$32.95
In stock
SKU
F1TNR-HC
  • Buy 20 for $31.95 each and save 3%

F1TNR-HC  Type-N Male Connector, Right Angle for FSJ1-50A, MFR: Andrew / Commscope

 

F1TNR-HC  Type-N Male Connector, Right Angle for FSJ1-50A

MFR: Andrew / Commscope

 

General Specifications  
Interface   N Male
Body Style   Right angle
Brand   HELIAX®
Mounting Angle   Right angle
   
Electrical Specifications  
Connector Impedance   50 ohm
Operating Frequency Band   0 – 6000 MHz
Cable Impedance   50 ohm
3rd Order IMD, typical   -112 dBm @ 910 MHz
3rd Order IMD Test Method   Two +43 dBm carriers
RF Operating Voltage, maximum (vrms)   565.00 V
dc Test Voltage   1600 V
Outer Contact Resistance, maximum   0.25 mOhm
Inner Contact Resistance, maximum   1.00 mOhm
Insulation Resistance, minimum   5000 MOhm
Average Power   0.4 kW @ 900 MHz
Peak Power, maximum   6.40 kW
Shielding Effectiveness   -110 dB
   
Outline Drawing  
   
Click on image below to enlarge.
   
   
   
Mechanical Specifications  
Outer Contact Attachment Method   Self-clamping
Inner Contact Attachment Method   Captivated
Outer Contact Plating   Trimetal
Inner Contact Plating   Gold
Interface Durability   500 cycles
Interface Durability Method   IEC 61169-4:17
Connector Retention Tensile Force   450 N   |   101 lbf
Connector Retention Torque   1.40 N-m   |   1.03 ft lb
Insertion Force   124.55 N   |   28.00 lbf
Insertion Force Method   IEC 61169-16:9.3.5
Pressurizable   No
Coupling Nut Proof Torque   1.70 N-m   |   1.25 ft lb
Coupling Nut Proof Torque Method   IEC 61169-16:9.3.11
Coupling Nut Retention Force   445.00 N   |   100.04 lbf
Coupling Nut Retention Force Method   IEC 61169-16:9.3.11
   
Dimensions  
Nominal Size   1/4 in
Diameter   22.35 mm   |   0.88 in
Height   20.62 mm   |   0.81 in
Length   51.70 mm   |   2.04 in
Weight   78.65 g   |   0.17 lb
Width   32.90 mm   |   1.30 in
   
Environmental Specifications  
Operating Temperature   -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature   -65 °C to +125 °C (-85 °F to +257 °F)
Immersion Depth 1 m
Immersion Test Mating   Mated
Immersion Test Method   IEC 60529:2001, IP68
Moisture Resistance Test Method   IEC 60068-2-3
Mechanical Shock Test Method   IEC 60068-2-27
Thermal Shock Test Method   IEC 60068-2-14
Vibration Test Method   IEC 60068-2-6
Corrosion Test Method   IEC 60068-2-11
   
Standard Conditions  
Attenuation, Ambient Temperature   20 °C   |   68 °F
Average Power, Ambient Temperature   40 °C   |   104 °F
Average Power, Inner Conductor Temperature   100 °C   |   212 °F

 

Return Loss/VSWR
Frequency Band VSWR Return Loss (dB)
824–960 MHz 1.08 28.3
1710–1880 MHz 1.12 24.94
1850–1990 MHz 1.12 24.94
1910–2200 MHz 1.14 23.69
2200–2700 MHz 1.16 22.61
3000–5000 MHz 1.18 21.66
5000–6000 MHz 1.25 19.08

 


More Information
Call For Price No
Featured Product No
Made in the USA No
NOS No
Manufacturer Name Commscope / Andrew