L4DR-PS 7/16 Andrew/CommScope Right Angle DIN Male LDF4-50A

$38.95
In stock
SKU
L4DR-PS
  • Buy 10 for $37.95 each and save 3%

DIN Male Right Angle Positive Stop™ for 1/2 in LDF4-50A cable
MFR: Andrew/CommScope
SKU: L4DR-PS

L4DR-PS 7-16 DIN Male Right Angle Positive Stop™ for 1/2 in LDF4-50A cable

MFR: Andrew / Commscope

 

General Specifications  
Interface   7-16 DIN Male
Body Style   Right angle
Brand   HELIAX®
Mounting Angle   Right angle
   
Electrical Specifications  
Connector Impedance   50 ohm
Operating Frequency Band   0 – 7500 MHz
Cable Impedance   50 ohm
3rd Order IMD, typical   -120 dBm @ 910 MHz
3rd Order IMD Test Method   Two +43 dBm carriers
RF Operating Voltage, maximum (vrms)   884.00 V
dc Test Voltage   2500 V
Outer Contact Resistance, maximum   1.50 mOhm
Inner Contact Resistance, maximum   0.80 mOhm
Insulation Resistance, minimum   5000 MOhm
Average Power   1.0 kW @ 900 MHz
Peak Power, maximum   15.60 kW
Insertion Loss, typical  0.05 dB
Shielding Effectiveness   -110 dB
   
Outline Drawing  
   
 Click on image below to enlarge.
   
   
   
Mechanical Specifications  
Outer Contact Attachment Method   Self-flare
Inner Contact Attachment Method   Captivated
Outer Contact Plating   Trimetal
Inner Contact Plating   Gold   |   Silver
Interface Durability   500 cycles
Interface Durability Method   IEC 61169-4:9.5
Connector Retention Tensile Force   890 N   |   200 lbf
Connector Retention Torque   5.42 N-m   |   48.00 in lb
Pressurizable   No
Coupling Nut Proof Torque   24.86 N-m   |   220.00 in lb
Coupling Nut Retention Force   1000.85 N   |   225.00 lbf
Coupling Nut Retention Force Method   MIL-C-39012C-3.25, 4.6.22
   
Dimensions  
Nominal Size   1/2 in
Height   41.91 mm   |   1.65 in
Length   82.45 mm   |   3.25 in
Right Angle Length   18.41 mm   |   0.72 in
Weight   166.90 g   |   0.37 lb
Width   34.60 mm   |   1.36 in
   
Environmental Specifications  
Operating Temperature   -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature   -55 °C to +85 °C (-67 °F to +185 °F)
Immersion Depth  1 m
Immersion Test Mating   Unmated
Immersion Test Method   IEC 60529:2001, IP68
Water Jetting Test Mating   Unmated
Water Jetting Test Method   IEC 60529:2001, IP66
Moisture Resistance Test Method   MIL-STD-202F, Method 106F
Mechanical Shock Test Method   MIL-STD-202F, Method 213B, Test Condition C
Thermal Shock Test Method   MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
Vibration Test Method   MIL-STD-202F, Method 204D, Test Condition B
Corrosion Test Method   MIL-STD-1344A, Method 1001.1, Test Condition A
   
Standard Conditions  
Attenuation, Ambient Temperature   20 °C   |   68 °F
Average Power, Ambient Temperature   40 °C   |   104 °F


Return Loss/VSWR
Frequency Band VSWR Return Loss (dB)
50–1000 MHz 1.02 -41.00
1000–1900 MHz 1.03 -36.00
1900–2200 MHz 1.06 -31.00
2200–2700 MHz 1.07 -29.00
2700–3600 MHz 1.09 -27.00
3600–6000 MHz 1.19 -21.00
6000–8800 MHz 1.67 -12.00


More Information
Call For Price No
Featured Product No
Made in the USA No
NOS No
Manufacturer Name TALLEY INC.